Steam Turbine Retrofits/Modernization Turbine Solution
Dongturbo Electric Company Ltd is one of the leading manufacturers and suppliers of steam turbine retrofits/modernization turbine solution in China. We warmly welcome you to buy high quality customized products at competitive price from our factory. Contact us for more cheap products.

Increase in turbine efficiency
1. Replacement of steam path with reactive blading with and without replacing of outer HP casing
2. Modernization of IP flow path LP
3. Replacement of springs in glands with cylindrical springs
Increase in turbine efficiency
1. Replacement of steam path with reactive blading with and without replacing of outer HP casing
2. Modernization of IP flow path LP
3. Replacement of springs in glands with cylindrical springs
Reduction of labour consumption for maintenance
1. Modernization of the monitoring system
Increase in power other technical characteristics
1. Controlled steam extraction for district heating
Reduction of capitalized expenses
1. Electro hydraulic protection against increase

HPC internal efficiency increase - 5.0 - 8.0 % | Efficiency increase - 5.0 % |
IPC internal efficiency increase- 1.5 - 3.0 % | Output increase – 25 MW |
LPC internal efficiency increase - 9.0 - 12.0 % |
Turbine K-200-130 (K-225-130), modernized HPC

1. Increased number of stages
2. Increased height of blades, smaller diameter of flow path
3. New effective airfoils of stationary and moving blades adjusted with flow inlet angles
4. Reactive type blading (new airfoils)
5. Decreased differential pressure at control stage
6. Internal efficiency increase: 5.0 - 8.0%

Single-sealing housing carrier design ensures as follows:
1. exclusion of buckling,
2. exclusion of damages to the strips of the sealing rings,
3. insensibility of gland to the temperature fluctuations,
4. exclusion of steaming,
5. increase in reliability,
6. reduction of scope and time of assembling works,
7. decrease in radial clearance values by 30 – 40%.
The gland of a similar design has been installed in turbine K-255-162at Alholma power station in Finland.
Output losses are reduced by 1000-1250 kW.
Turbine K-200-130 (K-225-130), modernized IPC

Integrally milled shrouds, welded diaphragms
Adjusted flow angles and airfoil angles
Smooth meridian contour
Developed diaphragm seals
New design of shroud seals

Single-sealing housing carrier design ensures as follows:
1. exclusion of buckling,
2. exclusion of damages to the strips of the sealing rings,
3. insensibility of gland to the temperature fluctuations,
4. exclusion of steaming,
5. increase in reliability,
6. reduction of scope and time of assembling works,
7. decrease in radial clearance values by 30 – 40%.
The gland of a similar design has been installed in turbine K-255-162at Alholma power station in Finland.
Output losses are reduced by 1000-1250 kW
Turbine K-200-130 (K-225-130), modernized LPC

1. Damping wires are eliminated from steam flow path
2. New steam flow path using stationary blades with tangential lean andlast stage moving blade of 960 mm
3. Integral milled shrouds, welded diaphragms
4. Adjusted flow angles and airfoil angles
5. Smooth meridian contour
6. Elimination of film moisture
7. Modernization of exhaust branch
8. Developed diaphragm seals
9. New design of shroud seals
Hot Tags: steam turbine retrofits/modernization turbine solution, China, manufacturers, suppliers, factory, customized, buy, cheap, EPC Of Coal Fired Power Plant, Power Plant Maintenance And Overhaul, Balance Of Plant Equipment Supply, Power Plant Retrofitting, Power Plant Turbine Blade, Power Plant Components And Parts
You Might Also Like
Send Inquiry