Main Technical Specifications
1. Model: C36-6.1/485-0.81
2. Type: medium temperature, medium pressure, single cylinder, impulse, extraction condensing steam turbine
3. Rated power (nameplate power): 36MW
4. Main parameters of pure condensing condition:
A) new steam pressure: 6.1MPa(a)
B) new steam temperature: 485℃
C) exhaust pressure: 0.007MPa(a)
D) main steam intake: 130t/h
E) generator power: 38196.2kw
Heat balance diagram please refer to Figure 1
5. Main parameters of 50t/h extraction condition:
A) new steam pressure: 6.1MPa(a)
B) new steam temperature: 485℃
C) exhaust pressure: 0.007MPa(a)
D) main steam intake: 130t/h
E) extraction pressure: 0.81MPa(a)
F) extraction volume: 50t/h
G) extraction temperature: 247.58℃
H) generator power: 28098.0kw
Heat balance diagram please refer to Figure 2
6. Main parameters of 75t/h extraction condition:
A) new steam pressure: 6.1MPa(a)
B) new steam temperature: 485℃
C) exhaust pressure: 0.007MPa(a)
D) main steam intake: 130t/h
E) extraction pressure: 0.81MPa(a)
F) extraction volume: 75t/h
G) extraction temperature: 247.58℃
H) generator power: 23341.8kw
Heat balance diagram please refer to Figure 3
7. Main parameters of 85t/h extraction condition:
A) new steam pressure: 6.1MPa(a)
B) new steam temperature: 485℃
C) exhaust pressure: 0.007MPa(a)
D) main steam intake: 130t/h
E) extraction pressure: 0.81MPa(a)
F) extraction volume: 85t/h
G) extraction temperature: 247.58℃
H) generator power: 21534.0kw
Heat balance diagram please refer to Figure 4
8. Main parameters of 90t/h extraction condition:
A) new steam pressure: 6.1MPa(a)
B) new steam temperature: 485℃
C) exhaust pressure: 0.007MPa(a)
D) main steam intake: 130t/h
E) extraction pressure: 0.81MPa(a)
F) extraction volume: 90t/h
G) extraction temperature: 247.58℃
H) generator power: 20659.3kw
Heat balance diagram please refer to Figure 5
9. Direction: clockwise (looking from turbine end to generator end)
10. Rated speed: 3000r/min (recommended generator rated speed: 3000r/min)
11. Flow stage: total of 20 stages (1 adjustment stage + 19 pressure stages) (determined during construction design
12. Adjust extraction position: after stage10th
13. Height of last stage rotor blade: 807mm (tentative)
14. Overall dimensions of turbine generator set: L × W × H = ~ 16060 mm × 6107.5 mm × 3800 mm (length from the center line of main steam valve inlet to the center line of excitation motor, height from the top of main steam valve oil motor to the height of operation platform).
15. Weight of turbine body: ~ 120 t (including valves, pipelines, base frame and shim)
16. Maximum lifting weight: ~ 25t (upper half cylinder during overhaul)
~ 27t (lower cylinder during installation)
17. Maximum lifting height: ~ 7.0m (from the operating platform)
18. Operating platform height: 8m (tentative)
19. Condenser area: 3750㎡
20. Design flow rate of cooling water: 8800t/h
21. Design inlet water temperature of cooling water: 28℃
22. Cooling water temperature rise: 7.444℃
23. Overall dimensions of condenser: L x W x H = 9364 mm × 3376 mm × 8600 mm.
24. Cooling water pipe material: Ti2
Hot Tags: 36mw extraction condensing steam turbine generator units, China, manufacturers, suppliers, factory, customized, buy, cheap, High Stability Generator, High Efficiency Steam Turbine, Advanced Boiler, 36MW Extraction Condensing Steam Turbine Generator Units, 5KW micro mini condensing steam turbine, 1MW Back Pressure Steam Turbine Generator Unit